100E The hardware lock has been disconnected, removed,
100E faulty or cannot be detected.
100S 1. If hardware lock has been removed or loosened,
100S please attach the hardware lock to the computer's
100S parallel port connector.
100S 2. Install the hardware lock driver from the CD-Rom,
100S if you have not done so.
100S 3. Should the hardware lock be damaged, please report
100S to your dealer.
101E Authorization File is incompatible or corrupted.
101S 1. Please copy the original Authorization File from
101S the Install CD-Rom/Disk to the main directory where
101S the program is installed.
101S 2. If the Authorization File is incompatible, please
101S contact your dealer.
103E -
103E Cannot support unlimited ('M') part qty.
103S Change the unlimited part qty to be limited.
104E -
104E Cannot support coiled stocks.
104S Change the coiled stock to be normal regular stock.
105E -
105E Cannot support unlimited ('M') part qty for tasks
105E with multiple distinct parts.
105S Change the unlimited part qty to be limited.
106E -
106E Cannot support coiled stocks for tasks
106E with multiple distinct parts.
106S Change the coiled stock to be normal regular stock.
107E Number of distinct stock sizes cannot be <=0.
107S Specify a num (>=1).
108E Number of distinct parts is greater than the actual
108E number of parts in the task file.
108E Add more parts in task file.
109E Number of distinct parts cannot be <=0.
109S Specify a num (>=1).
110E
110E Invalid number of parameters.
110E
110E Format : program_name task_name
110E
110E Example : NESTPRO task1
112E For "UpdateNest", the part output format should be
112E set to "DWG".
112S Run "SYSDATA" to re-set the "File Format" to "DWG".
114E Coiled stock and unlimited ('M') part qty
114E is not supported.
114S 1. Either change the stock definition.
114S 2. Or change part qty "M" to a fixed qty.
115E Assembly/Cluster needs more qty for the following part -
115S Please re-define the part qty.
130E No .DXF files found in directory -
130D The AutoNEST data files cannot be found in default
130D directory. Check part directory in <SYSDATA>.
131E No .VEC files found in directory -
131D The AutoNEST data files cannot be found in default
131D directory. Check part directory in <SYSDATA>.
133E No .SYM files found in directory -
133D The AutoNEST data files cannot be found in default
133D directory. Check task directory in <SYSDATA>.
134E No .DWG files found in directory -
134D The AutoNEST data files cannot be found in default
134D directory. Check part directory in <SYSDATA>.
134D Only applicable for AutoCAD.
136E No .STK files found in directory -
136D The AutoNEST data files cannot be found in default
136D directory. Check part directory in <SYSDATA>
140E Can't open file for read -
140D The error will happen when AutoNEST cannot open
140D the data file for read.
140D Eg, In <Nesting>, please make sure that the task file
140D and the part files are in the specified default
140D directories.
141E Can't open AutoNEST file for read -
141D The AutoNEST supporting files are missing or corrupted.
141S Check the AutoNEST distribution diskettes, and re-load
141S the necessary files onto the hard-disk.
142E Can't open file for read -
142D Need to create the above data file.
143E Authorization file not found.
143S Please consult your dealer.
144E All concurrent user licenses are currently being used.
144S Please wait a while until one of the licenses has
144S been released.
144S You can also contact your dealer to increase the
144S network concurrent user licenses.
145E Your current license is not for this product.
145S Please contact your dealer.
146E Trial license has expired.
146S Please contact your dealer.
147E Authorization License Code not found.
147S Submit the "Locking Code" and the
147S "License Code Request Form" duly filled-in to your dealer.
148E The system date has been tampered with.
148S Please contact your dealer.
149E Can't open file for read -
149D The error will happen when AutoNEST cannot open
149D The data file for read.
149S 1. The Task must be NESTED first before Auto-Bridge can be
149S performed.
149S 2. Make sure that the Part & Task directories are correctly
149S specified in the SYSDATA.
150E Can't open file for write -
150D The error will happen when AutoNEST cannot open
150D the data file or supporting file for write.
150S 1. Run Out of File Handle, increase the "FILE" field in
150S config.sys.
150S Eg FILES=20
150S 2. Hard Disk Full.
151E Can't open file for append
151D The error will happen when AutoNEST cannot open
151D the data file or supporting file for write.
151S 1. Run Out of File Handle, increase the "FILE" field in
151S config.sys.
151S Eg FILES=20
151S 2. Hard Disk Full.
153E The AutoNEST file is corrupted -
153E Check the AutoNEST distribution diskettes, and re-load
153E the necessary files onto the hard-disk.
154E The file is corrupted -
154S Report to AutoNEST dealer
155E The following part(s) cannot be found in the job file.
156E No part found in the job file.
157E No part selected.
158E No stock selected.
159E Cannot find job file, therefore ViewNEST terminates here.
160E "Pre-defined" parts cannot be read.
160D This is a trial version, only "pre-defined" parts
160D in the default "...\parts" directory can be nested.
160S Change the "Part/Ir-Stock Directory" to the
160S installation default "...\parts" directory and try again.
201E No suitable stock size at all
201D During nesting if all the declared stock sizes are
201D found to be too small to nest even one or a pair of the
201D smallest part in the task, this message will be displayed.
201S Either increase the stock sheet size or nest smaller parts.
202E Number of distinct parts exceeds 1000.
202D The number of distinct parts submitted in the task file
202D has exceeded the limit of 1000.
203E Number of distinct stocks exceeds 500.
203D The number of distinct stocks submitted in the task file
203D has exceeded the limit of 500.
204E Part profile has more than 1500 vertices -
204D The number of vertices in one of the profile of the part
204D has exceeded the maximum number allowed : 1500.
205E No nesting layout meets minimum utilization ratio requirement.
205D All nesting layouts are abandoned.
205S Either change stock size or set a lower minimum utilization ratio
206E Ir-stock profile is out of processing limit.
206D This may be due to too many vertices in the ir-stock
206D profile or too many holes defined inside the ir-stock.
206S Please simplify the ir-stock profile or try to reduce
206S the no of holes inside the ir-stock.
300E Incompatible AutoNEST version -
300D Error happens when data file is from a different version
300D of AutoNEST. For eg, the data file for AutoNEST V9
300D will contain the following comment line :
300D "# AutoNEST V9"
300D The Release no is used to check the compatibility of
300D different formats of data files between different releases.
300D AutoNEST provides downward compatibility for all the
300D data files.
300S Please make sure all the files are not corrupted and
300S the Release No is properly designated.
300S If the file is corrupted, re-create the file.
305E Profile(s) not closed or contains irregularities at the following location(s) :
305S Either re-create the part/ir-stock or change the aperture
305S value in ANEST.TOL.
306E Profile(s) not closed or contains irregularities -
306S Either re-create the part/ir-stock or change the aperture
306S value in ANEST.TOL.
307E Profile has lines that CROSSES over -
307D The profile has some intersection lines.
307S Either re-create the part or change the aperture value
307S in ANEST.TOL.
308E Profile has multiple SAME point -
308S Either re-create the drawing or change the aperture value
308S in ANEST.TOL.
312E Profile is an ACAD Block - need to EXPLODE
312D Only applicable for AutoCAD
312S Re-create the drawing.
313E Profile contains SPLINE segment -
313D AutoNEST cannot accept profile with "SPLINE" segment
314E Cannot convert DXF file -
314D No profile can be detected on the LAYER or of the COLOR
314D as specified in the SYSDATA "Input Part/Ir-Stock
314D - Layer Setting".
315E Part has TOO MANY EDGES -
315D The constraints for vector compression is too tight.
315S Change the constraints in ANEST.SYS.
315S Either decrease minimum vector, increase total area, or
315S increase relative global tolerance.
340E Invalid file format for -
340S Need to re-do
341E Invalid file format for AutoNEST supporting file -
341S Need to re-load from Diskette
345E Cannot find "ANEST" layer in .DXF file -
345S Need to save blocks in "ANEST" layer.
350E Cannot find BLOCK in .DXF file -
350S Need to re-create file
351E Cannot find ENTITIES in .DXF file -
351S Need to re-create file
352E The .DXF file is above R12 version -
352D Current software cannot support part/ir-stock
352D DXF file above R12 version in Nest Manager environment.
352S Save your part/ir-stock .DXF file as in R12 format.
400E Not all parts are nested. It is due to either insufficient stock or
400E no suitable stock size found.
400E For more information, look at the summary.
401E Pattern type of the following boundary data is wrong -
402E Some parts are not nested as nested layout is below
402E Utilization Factor.
402E For more information, look at summary / schedule.
403E Profile(s) not closed or contains irregularities at the following location(s) :
403D This profile(s) will be ignored during nesting.
403D Please check the profile(s) carefully, especially for
403D outer-profile. Then save again to ensure correct nesting result.
404E Current program can only support 0,90,180 degrees for stock
404E grain direction. Other angles are ignored during nesting.
405E The following changed or missing part(s) are recovered back:
405D This is a trial version, only "pre-defined" parts can be nested.
405D The "pre-defined" parts are not allowed to be modified.
406E The following custom part(s) cannot be nested:
406D This is a trial version, only "pre-defined" parts can be nested.
406S Delete the custom part(s) from the Task and nest again.
500E Not Enough Memory.
500D Error due to insufficient memory to execute the AutoNEST program.
500S Remove all unnecessary memory-resident programs.
500S If in AutoCAD environment, check acad.pgp for memory reserve
500S for all the programs. If possible, increase the memory reserve
500S for the program. [For more information, please refer to AutoCAD
500S Reference Manual, Appendix B]
600E Pointer out of range
600D Software bugs.
600S Report to AutoNEST Dealer.
601E Array Out Of Range
601D Software bugs.
601S Report to AutoNEST Dealer.
602E Part expansion error -
602E Expanded part contains invalid geometry
602D The part after expansion to the specified cutting gap
602D may contain invalid geometry or the number of vertices
602D of the expanded part exceeds the limit : 350 vertices.
602S Re-create the part by reducing the number of vertices.
602S This may help to solve the problem. If not, Report it to
602S AutoNEST Dealer.
652E Nesting Error: -
652E Report to AutoNEST Dealer